Why You Should Not Mix Roof Exhaust Vents

Two exhausts on one attic will often pull air from each other instead of from the eaves. Pick one type and fix the intake.

  • Intermediate
  • 2 to 4 hours
  • Updated

The short answer

Do not mix exhaust vent types on one attic. A ridge vent beside box vents, a turbine, a gable vent or a power vent lets air enter the lower vent and leave through the higher one, short circuiting the attic so the eaves and lower roof stay stagnant. Choose one exhaust type, size it by net free area, balance it with soffit intake and remove or seal the others.

Mixing exhaust vents sounds sensible: more vents, more airflow. In practice it often reduces ventilation where you need it. The reason is how air takes the path of least resistance. A ridge vent beside a row of box vents, a power vent in a gable, or a gable vent in a roof that also has a ridge vent creates short paths between the exhaust vents, so air goes in one and out the other without travelling through the whole attic.

The result is stagnant areas, especially along the eaves and the lower part of the roof deck, where damp air lingers and mold grows. It is a common finding on Fraser Valley roofs that have been added to over the years: a ridge vent added to a roof that already had box vents, or a power vent added because the attic felt hot.

This guide explains why it happens and what to do about it. For the basics, see how attic ventilation works. For installing one type well, see how to install a ridge vent and how to install box vents.

Tools

  • Flashlight
  • Tape measure
  • Calculator
  • Ladder
  • Roofing hammer and flat bar if removing vents
  • Utility knife

Materials

  • Replacement shingles and roofing underlayment, or cover plates, to close old vent openings
  • Plywood or metal patch plates
  • Roofing nails
  • Plastic cement where specified

Safety first

  • Work tied off. WorkSafeBC requires fall protection at 3 metres (about 10 feet) and wherever a fall could cause serious injury.
  • If a power vent is wired, turn off and lock out the circuit before removing it.
  • Do not step on attic drywall. Use boards laid across joists.

Step by Step

  1. Step 1: Count the exhaust vents on your roof

    From the ground, look for roof vents at the ridge and on the roof face, and gable vents at the ends. In the attic, look for fans or thermostats from power vents. Write down each type and how many there are.

    If there is more than one type of exhaust, the roof is mixed. Also check bath fans, see how to vent a bathroom fan through the roof, because a fan venting into the attic is a moisture source, and it is not an exhaust vent in this sense.

  2. Step 2: Understand how the short circuit happens

    A ridge vent and a lower exhaust vent both work as outlets. The pressure difference between them is small but direct. Air is pulled in at the lower vent and leaves at the ridge, and the intake air from the soffit has little pull on it. The eaves stay dead.

    Power vents make it worse. A fan in the roof pulls hard and can draw air through the ridge vent and gable vents, or from the soffits or from the house through the ceiling, rather than where you want it.

    Tip: Rain and snow can also be pulled in through the lower vent when the ridge vent is pulling, since the lower vent is acting as an intake.

  3. Step 3: Choose one exhaust type

    A continuous ridge vent gives the most even exhaust and is the usual first choice when the ridge is long enough. On a short or cut-up ridge, a row of box vents may be the better single choice, but use one or the other.

    Gable vents are a separate question. On roofs with gable vents and a ridge vent, the gable vents can short circuit the ridge, and they depend on wind direction. They are best removed or sealed when a ridge vent is installed, unless the design specifically accounts for them.

  4. Step 4: Size the single exhaust by net free area

    Use the calculation in how to calculate attic ventilation. The BC Building Code asks for vent area not less than 1/300 of the insulated ceiling area, or 1/150 for low slope or joist roofs, split about half intake and half exhaust.

    If the ridge alone cannot give enough exhaust, choose a ridge vent with a higher rating per foot, or use a single type of box vents instead. Do not add a second type to make up the difference.

  5. Step 5: Make sure intake is at least equal to exhaust

    If you remove exhaust vents, you may find there was too much exhaust already. Intake should be at least as large as exhaust. See how to add soffit intake vents and how to install insulation baffles.

    A good ridge vent with open soffit intake does the job of several mixed vents.

  6. Step 6: Remove or seal the extra exhaust vents

    For box vents and turbines, remove the vent, patch the deck with plywood and shingle over the patch, lapping the new shingles correctly. For a power vent, disconnect the wiring safely, remove the unit and close the hole the same way.

    For gable vents, block them from inside with rigid foam or plywood, or cover them outside. Seal any vents that remain so they do not act as a second exhaust or intake.

  7. Step 7: Check the result

    With one exhaust and a clear intake, you should feel air moving at the soffit, see daylight at the vents and find dry sheathing. Mold or damp that was present before may take a dry spell to go away. See how to fix attic mold caused by poor ventilation for treatment.

Combinations That Cause Trouble

  • Ridge vent plus box vents: the box vents pull air in or short circuit with the ridge.
  • Ridge vent plus gable vents: wind through the gables bypasses the ridge and eaves.
  • Power vent plus ridge vent: the fan can pull air through the ridge vent instead of the soffits.
  • Turbines plus anything else: turbines turn only in wind and leave dead zones on calm days.
  • Gable vents plus soffit vents: can work on a simple roof but depend on wind and leave corners dead.

Power Vents and Moisture

A power vent pulls air strongly. If intake is short, it draws air from the house through ceiling gaps, taking warm moist air into the attic and raising heating costs. In a wet climate that makes the problem worse. Passive, balanced ventilation is usually more reliable than a fan.

Common Mistakes

  • Adding a ridge vent and keeping the old box vents. The two short circuit.
  • Adding a power vent to a roof with other vents. It pulls air from the wrong places.
  • Leaving gable vents open with a ridge vent. Wind passes straight through the attic.
  • Closing old vent holes with only sealant. The openings need a proper patch and shingling.
  • Adding more exhaust to fix a damp attic. The problem is usually intake or moisture sources.
  • Ignoring intake. A single exhaust still needs soffit vents.

When to Call a Professional

If the roof has a mix of vents and you are not sure which to keep, or the roof is high or steep, a roofer can lay out a single system and close the old openings properly. Patching old vent holes in a roof is best done by someone who can shingle them cleanly.

If the attic has mold, sort out the cause first, see how to fix attic mold caused by poor ventilation.

Fraser Roofing does free roof inspections across the Fraser Valley, from Hope to Abbotsford. See our Roof Replacement service or the towns we cover.

Why You Should Not Mix Roof Exhaust Vents: Questions

Can you have a ridge vent and box vents?

It is not recommended. Air can enter the lower box vents and leave through the ridge vent, bypassing the rest of the attic, so the eaves stay stagnant. Use one exhaust type for the whole roof. If you add a ridge vent, remove or seal the box vents and make sure the soffit intake is open.

Should I remove gable vents if I install a ridge vent?

Usually yes. Wind blowing across gable vents can pull air straight through the attic from one end to the other and bypass the soffit to ridge flow. Blocking the gable vents from inside, or covering them outside, lets the ridge vent and soffit intake work as a system.

Is a power attic fan a good idea?

Usually not as a first choice. A fan pulls strongly and, without enough intake, draws air from the house through ceiling gaps, carrying warm moist air into the attic. It can also short circuit other vents. Balanced passive ventilation, with soffit intake and one exhaust type, is generally more reliable.

Why is more exhaust not better for attic ventilation?

Airflow depends on intake as much as exhaust. Extra exhaust vents do not add air if the soffits are blocked, and they pull air from wherever it is easiest, including the house below. More exhaust also creates short paths between vents. Balanced intake and a single exhaust type do the job.

Related Guides

How Attic Ventilation WorksAttic ventilation works by letting outside air enter low at the soffits and leave high at the ridge or roof vents, so rising warm air pulls fresh air through. It removes moisture in winter and heat in summer. The BC Building Code asks for unobstructed vent area of at least 1 in 300 of the insulated ceiling area, or 1 in 150 for low slope or joist roofs, with intake and exhaust balanced.How to Install a Ridge VentTo install a shingle-over ridge vent, cut a slot along the ridge through the deck, commonly 1 to 2 inches wide on each side of the ridge board, and stop about 12 inches short of each end. Centre the vent over the slot, nail it with longer nails that reach the framing, then cover it with ridge cap shingles. Choose a baffled vent so wind and rain do not blow in.How to Install Box (Static) Roof VentsTo install a box vent, locate it on the roof face near the ridge, between rafters, cut a hole to the vent's template, slide the flange under the shingles above, nail the flange on the top and sides, and lap the shingles below over it. Space vents evenly along the ridge side of the roof, and choose the count from the net free area on the label.How to Calculate Attic VentilationTo calculate attic ventilation, measure the insulated ceiling area in square feet, divide by 300 (or by 150 for roofs under 1 in 6 slope or with roof joists), then multiply by 144 to get square inches of net free area. Split that total about equally between intake and exhaust. Divide each half by the net free area printed on the vent label to get the number of vents or feet of ridge.How to Add Soffit Intake VentsTo add soffit intake vents, calculate the intake net free area you need, cut openings in the soffit between rafters or swap solid soffit for vented or perforated panels, and fit screened vents. Then make sure the air can get in: clear paint and debris, and install baffles so insulation does not cover the opening. Spread vents evenly along both eaves.How to Fix Attic Mold Caused by Poor VentilationAttic mold comes from moisture, not from mold. Find the source first: bath fans or dryers venting into the attic, blocked soffit intake, air leaks from the house and too little exhaust. Fix those, let the sheathing dry, then clean light surface mold or replace badly affected wood and insulation. Large areas, wet insulation or health concerns call for professional remediation.

All Ventilation and Attics guides|The full How-To Library

This guide is general education. Always follow the product manufacturer's installation instructions, the BC Building Code and WorkSafeBC requirements, which take priority over anything written here.

Want someone to look at your roof?

Kory & Johnny have roofed homes across the Fraser Valley since 2016. Free inspections, honest estimates, no pressure.

604-728-0146Text UsEmail

Serving Hope, Agassiz, Chilliwack, Rosedale, Abbotsford & the entire Fraser Valley

$1,000 off applies to full roof replacements of 3,000 sq ft or more. Cannot be combined with other offers or previously placed orders. Not valid on partial jobs, repairs, or insurance claims.

We use cookies and the Meta Pixel. Meta receives information about your visit and uses it to measure our ads and show you ads. Decline turns it off. Privacy policy